| Sizing a Heat Exchanger for Cold Plate Applications |
In many liquid cooling loops, the heat that is picked up by a cold plate is rejected to the ambient air via a heat exchanger. Since the components are part of a system, it is important to select them together to ensure proper component sizing for your application. So how do you select the optimal heat exchanger for the complete system? It is easier than you might think, since the equations needed to determine the right cold plate and heat exchanger combination reduce to a very simple format... |
|
|
 |
 |
February 2007
Published on February 25, 2007
|
|
|
 |
CUSTOM RECIRCULATING CHILLER COOLING SYSTEMS Compressor-based recirculating chillers are often used to cool lasers and medical equipment, as they can provide the cooling and precise temperature control needed for these applications. One of Lytron’s customers needed a recirculating chiller that had a cooling capacity of 2kW, a maximum weight of 75 lbs (34 kg), and a height limit of 12.75 inches...
THERMAL INTERFACE MATERIALS AND COLD PLATES Bergquist assisted Lytron, manufacturer of cold plates, cooling systems, and heat exchangers, with an article on thermal interface materials for Lytron's customers. To be effective, all cold plates require intimate surface-to-surface contact with the component or board-to-be-cooled.
MACROFLOW VERSION 2.9 Version 2.9 Includes Many New Capabilities for Designing Liquid-Cooled Electronics Systems and Fluid Delivery Systems in Semiconductor Processing
LASER CUTTING SYSTEM FROM FICO ACHIEVES 40X PERFORMANCE ENHANCEMENT AFTER ENGINEERING FLUID DYNAMICS ANALYSIS Fico, member of the Besi Group, used engineering fluid dynamics analysis software EFD.Pro to obtain an amazing 40x performance enhancement in their new laser cutting system. The company successfully optimized airflow in their new equipment to deal with the dust created as a result of
|
|
 |
 |
 |
 |
|
|
|
 |
ATS, NTS PAIR ON TEST, DESIGN SERVICES Advanced Thermal Solutions (ATS) , the world-class provider of testing and design services and products to cool electronic equipment, has partnered with National Technical Systems (NTS), the leading provider of conformance and certification testing, quality registration, and managed services.
ANCIS OPTIMIZES DATA CENTER COOLING WITH FLOVENT CFD SOFTWARE ANCIS Incorporated, a San Francisco based consultancy, recently helped a major telecom firm develop a greatly improved HVAC design standard for its central offices (COs) using Flomerics’ Flovent computational fluid dynamics (CFD) software to predict air intake temperatures for sensitive electronic equipment.
DESIGNING A LIQUID COOLING LOOP - FREE WEBINARS Lytron is sponsoring live 1-hour webinars on March 7th at 9:00AM EST/3:00 PM CET and March 14th at 4:00PM EST/1:00PM PST. The webinars will be taught by Dr. Cathy Biber and will provide a 1-hour overview of some of the challenges in designing a liquid cooling loop.
|
|
 |
 |
 |
 |
|
|
|
|
 |
 |
 |
 |
LINKS |
|
|