the iq-200 from advanced thermal solutions, inc. (ats) is designed to be used wherever temperature, pressure and velocity measurements are required. it was named a nasa tech briefs product of the month in july 2014.
the iq-200™ is the only system available on the market that provides the user with the capability to simultaneously or individually measure all of the required thermal parameters with one system.
the iq-200™ eliminates the need for having multiple systems or additional software to synchronize data collection of different parameters. the iq-200™ is a compact, portable and versatile system that minimizes lab clutter.
the iq-200™ measures temperature with 12 thermocouple ports supporting j, k, t and e types, with a range of -40 to 750ºc. air temperature is measured by sixteen thermister ports (also used for velocity measurement) with a range of -10 to 85ºc.
16 hot wire anemometer ports measure velocity using ats single-sensor technology, requiring no need to change sensors when measuring different velocity ranges. the standard range for velocity measurement is 0 to 6 m/s (0 to 1200 ft/min) and for custom calibration, the range is 0 to 50 m/s (0 to 10,000 ft/min). the iq-200™ also supports ats’ unique, patented candlestick sensor.
pressure is measured by 4 ports, supporting differential or absolute pressure, with a range of 0 to 1,035pa (0 to 0.15 psi).
the user-friendly, labview™- based iqstage™ data acquisition software is included in the system. iqstage™ manages incoming data from various sensors and provides a rich graphical presentation of the results. iqstage™ eliminates data collection errors induced because of measurement time lapses or transience associated with the use of multiple systems.
product specifications
- overall dimensions (d x w x h): 43 x 34 x 12.6cm (17 x 13.3 x 5")
- number of sensor ports (velocity): 16
- number of thermocouple ports (j, k, t & e types): 12
- number of sensor ports (pressure): 4
- flow range: 0 to 50 m/s (0 to 10,000 ft/min)
- flow uniformity: +/- 1%
- temperature range: -40 to 750ºc (-40 to 1382ºf)
- temperature accuracy: +/- 1ºc
pressure range: 0 to 1,035pa (0 to 0.15psi)
- pressure accuracy: +/- 1%
- power: 110 or 220v (international)
- weight: 7.5 kg (15 lbs)
- software: iqstage™
- connection: usb port
iq-200™ applications
- heat sink design & selection
- pcb characterization
- card rack characterization (atca, picmg, 1u, etc.)
- qualification testing in the environmental chamber (nebs, milspec, etc.)
- mockup testing
- wind tunnel testing of cards, heat sinks, components, etc.
additional features
- simultaneous or individual temperature, velocity & pressure measurement
- saves time & lab space
- unique iqstage™ software
- compact, portable & versatile
- 12 thermocouple ports (j,k,t & e types) for temperature measurement
- 16 sensor ports for velocity measurement
- 4 ports for pressure measurement
|