norwood, ma, april 15, 2012 --(pr.com)-- advanced thermal solutions, inc., ats, is teaching engineers how to calculate the thermal loads in common liquid cooling systems. calculations of this nature are needed to predict the performance of liquid cooling systems, which are effective but complex thermal management solutions. several equations must be calculated to fully understand the behavior of a liquid cooled system, and ats is providing these to engineers via personal instruction and in a paper available free from the company’s website, qats.com.

in the paper, which appears in the company’s e-magazine, ats considers a liquid cooling system as a closed loop system with three major components: cold plate, heat exchanger and pump. the cold plate is typically made from aluminum or copper, and is attached to the device being cooled. the plate usually has internal fins, which transfer heat to the coolant flowing through them. this fluid moves from the cold plate to a heat exchanger where its heat is transferred to the ambient air via forced convection. the final part of the cooling loop is the pump, which drives the fluid through the loop.

a series of equations is provided to predict the final temperature of the device being cooled. the first of these equates the surface temperature of this device with the product of the power dissipated by the device times the thermal resistance of the cold plate (and its thermal interface material), added to the temperature of the water entering the cold plate.

the sequence of calculations factors in specifications from the cold plate, heat exchanger and pump. the result is a solution for the device temperature as a function of cold plate resistance. in the example cited by ats, a cold plate thermal resistance of less than 18 degrees c/w is required to cool an intel xeon 5492 processor in a 25c temperature environment.

liquid cooling is an important and expanding practice in the electronics industry. it is important to understand the impact on performance of all three major parts of liquid cooling loops (cold plate, heat exchanger and pump) to ensure an acceptable level of performance at the lowest cost.

instructions for calculating load for liquid cooling systems are available on qats.com in the pages of qpedia, the thermal management emagazine from ats. more information is also available by calling 1-781-949-2522.

Choose category and click GO to search for thermal solutions

 
 

Subscribe to Qpedia

a subscription to qpedia monthly thermal magazine from the media partner advanced thermal solutions, inc. (ats)  will give you the most comprehensive and up-to-date source of information about the thermal management of electronics

subscribe

Submit Article

if you have a technical article, and would like it to be published on coolingzone
please send your article in word format to [email protected] or upload it here

Subscribe to coolingZONE

Submit Press Release

if you have a press release and would like it to be published on coolingzone please upload your pr  here

Member Login

Supplier's Directory

Search coolingZONE's Supplier Directory
GO
become a coolingzone supplier

list your company in the coolingzone supplier directory

suppliers log in

Media Partner, Qpedia

qpedia_158_120






Heat Transfer Calculators